Column Section
Materials
Main Reinforcement
Column Applied Loads
Punching Shear — Slab Data
P-M Interaction Diagram + Cross Section
Capacity — P-M Check
φPn max
kN
φMn max
kN·m
ρg Steel
%
Interaction
P-M Check
Tie Spacing — ACI 318M §25.7.2.1
16 × db
mm
Criterion 1
48 × dt
mm
Criterion 2
min(b, h)
mm
Criterion 3
s max (governs)
mm
Min of 3

Capacity & Ties — Key Values

Slenderness & Buckling — ACI 318M §6.2
klu / r
Slenderness Ratio
Column Type
Classification
Pcr (Euler)
kN

Slenderness Calculations

ACI 318M §6.2.5 — Slenderness Limits Short column: klu/r ≤ 22 (braced frame). Long column: moment magnification required §6.6.4. klu/r > 100: nonlinear 2nd-order analysis required. r = 0.30h for rectangular sections.
ACI 318M Load Combinations — Slab
Combination wu (kN/m²) Vu tributary (kN) Vu punching (kN) φVc (kN) DCR Status
Punching Shear Check — ACI 318M §22.6
Vu governing
kN
From slab loads
φVc (capacity)
kN
DCR = Vu/φVc
Demand / Capacity

Punching Shear Calculations

ACI 318M §22.6.5 — Three Vc Equations (Minimum Controls) ① 0.17(1+2/β)λ√f'c·bo·d  |  ② 0.083(αs·d/bo+2)λ√f'c·bo·d  |  ③ 0.33λ√f'c·bo·d. φ = 0.75. Critical perimeter bo at d/2 from column face. Vu = wu × (Lx × Ly) − wu × (b+d)(h+d) per ACI §22.6.4.1 for interior columns.
Design Summary — All Checks

Complete Section & Load Properties